TM 9-4120-425-14&P
LOUVER ACTUATOR CABLES UNIT MAINTENANCE
THIS WORK PACKAGE COVERS:
Removal, Repair, Installation and Adjustment
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Tool Kit, General Mechanics (Item 1, Table 2, WP 0118-00)
Materials/Parts
See WP 0094
Equipment Condition
Air conditioner shut down and cool.
Rear top panel and canvas cover removed (WP 0018-00 and WP 0019-00).
WARNING
Disconnect air conditioner power input connector before doing maintenance work on
electrical system.
REPAIR
Repair of louver actuator cables is limited to replacement of defective or damaged components. Failure of louvers to
open/close properly may indicate binding of the cable. If so, a louver actuator cable product improvement kit may be
required. Contact proponent item manager.
REMOVAL
1.
Remove screw (1) and cable clip (2).
2.
Remove two screws (3) and two mechanical posts (4) attaching louver actuator cables (5) and (6) to louver actuator
(19).
3.
Release four nuts (7) from cables (5) and (6).
4.
Remove two mechanical posts (8) and screws (9) from ends of louver actuator cables (5) and (6). Release four nuts
(10) from cables.
5.
Pull cables out of angle (12) on condenser fan scrolls (13) and (14).
6.
Remove two nuts (10) from angle (15).
7.
Pull cables through control bracket (11) and angle (15), and remove cables.
8.
Remove four screws (16), four lock washers (17), bracket (18), and control bracket (11).
9.
Rivnuts (20) remain in place unless damaged.
0032-01-1
|