REPAIR CONTINUED
Figure 7. Water Pump Return Hose.
13. Slide one clamp (Figure 7, Item 1) over water pump return hose (Figure 7, Item 3) and tighten securely. Do not
over tighten.
14. Slide one clamp (Figure 7, Item 2) over water pump return hose (Figure 7, Item 3) at water pipe (Figure 7,
Item 5) and tighten securely. Do not over tighten.
15. Flush cooling system in accordance with this WP.
16. Refill cooling system in accordance with this WP.
17. Operate engine for sufficient time to check all connections for leaks (TM 10-8415-222-10, Operating
Procedures).