TM 10-8145-222-23
0026
REPAIR CONTINUED
18. Install top-right panel (WP 0013, Install).
19. Install front panel assembly (WP 0013, Install).
20. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
Replace Water Pump Supply Hose
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
2. Compress two clamps (Figure 8, Item 1 and Item 2) securing water pump supply hose (Figure 8, Item 3) to
water pump (Figure 8, Item 4) and thermostat housing (Figure 8, Item 5) and slide clamps towards center of
hose.
3. Disconnect water pump supply hose (Figure 8, Item 3) from water pump (Figure 8, Item 4).
4. Disconnect water pump supply hose (Figure 8, Item 3) from thermostat housing (Figure 8, Item 5).
5. Remove water pump supply hose (Figure 8, Item 3).
6. Remove two clamps (Figure 8, Item 1 and Item 2) from water pump supply hose (Figure 8, Item 3).
7. Clean and dry water pump (Figure 8, Item 1 and Item 2) and thermostat housing flanges (Figure 8, Item 5).
8. Compress two clamps (Figure 8, Item 1 and Item 2) on replacement water pump supply hose (Figure 8, Item 3)
and position loosely towards center of hose.
9. Install one end of replacement water pump supply hose (Figure 8, Item 3) onto thermostat housing flange
(Figure 8, Item 5).
10. Compress and slide one clamp (Figure 8, Item 2) over water pump supply hose (Figure 8, Item 3) at thermostat
housing flange (Figure 8, Item 5).
11. Install opposite end of water pump supply hose (Figure 8, Item 3) onto water pump (Figure 8, Item 4).
12. Compress and slide one clamp (Figure 8, Item 1) over water pump supply hose (Figure 8, Item 3) at water
pump (Figure 8, Item 4) flange.
0026-15