TM 10-8145-222-23
0030
REPLACE CONTINUED
27. Keeping tension on the alternator (Figure 5, Item 4), tighten self-locking nut (Figure 5, Item 3) and bolts
(Figure 5, Item 1 and Item 2).
CAUTION
Overtightening of nuts on studs will cause damage to the alternator.
28. Using tags on wiring harness (Figure 5, Item 15) to identify connection points, connect wiring harness (Figure 5,
Item 15) to back of alternator (Figure 5, Item 4) and secure with nuts (Figure 5, Item 13) and washers (Figure 5,
Item 14).
29. Position angle bracket (Figure 5, Item 11) on alternator (Figure 5, Item 4) and secure with four bolts (Figure 5,
Item 8), new lock washers (Figure 5, Item 9), and stand-offs (Figure 5, Item 10).
NOTE
If strain relief was loosened, then it will be necessary to tighten the strain relief. When
selecting a location on cable to tighten the strain relief, it is important to leave enough
cable between the alternator cover bracket and the alternator to facilitate future
maintenance.
30. Tighten strain relief (Figure 4, Item 12), if necessary.
31. Check alternator V-belt tension (WP 0035, Adjust).
32. Install top-middle panel (WP 0013, Install).
33. Place emergency stop switch (Figure 3, Item 1) in PULL TO START position.
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
34. Climb off top of MTRCS using roof access provided.
35. Place POWER ON/DOWN switch (Figure 2, Item 2) on control panel to ON position.
36. Start refrigeration unit (TM 10-8415-222-10, Operating Procedures).
37. Test alternator per this WP.
38. Close control panel access door (Figure 2, Item 1).
39. Place MTRCS back into mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0030-8