TM 10-8145-222-23
0052
REPLACE CONTINUED
Install
1. Slide locking nut (Figure 11, Item 11) over wires and onto replacement cable assembly P2A (Figure 11,
Item 10) by compressing cord mesh allowing it to slide easily along cable.
2. Slide cord mesh (Figure 11, item 12) over wires and onto replacement cable assembly P2A (Figure 11,
Item 10).
3. Slide rubber grommet (Figure 11, Item 13) over cable to seat on cord mesh collar (Figure 11, Item 12).
NOTE
There will be approximately three feet of un-terminated wiring for S1 connections
(three places); two feet of wire for transformer TR1 terminal X0 connection and one
foot of wire for GND connection that will be routed inside of the power box. These
individual wires will be outside of the insulated cable jacket and will not be exposed
to environmental conditions outside of the power box.
4. Carefully guide replacement cable assembly P2A (Figure 11, Item 10) wires into power box (Figure 11, Item 4).
5. Route three wires (red, black, and orange) to switch S1 (Figure 11, Item 2).
6. Connect red wire at switch S1 (Figure 11, Item 2) terminal S1-3 (Figure 2) and tighten terminal screw (Figure
11, Item 5). Tighten screw 20 to 25 inch-pounds of torque (WP 0091).
7. Connect black wire at switch S1 (Figure 11, Item 2) terminal S1-7 (Figure 2) and tighten terminal screw (Figure
11, Item 5). Tighten screw 20 to 25 inch-pounds of torque (WP 0091).
8. Connect orange wire at switch S1 (Figure 11, Item 2) terminal S1-11 (Figure 2) and tighten terminal screw
(Figure 11, Item 5). Tighten screw 20 to 25 inch-pounds of torque (WP 0091).
9. Route white neutral wire to transformer TR1 (Figure 11, Item 3).
10. Connect white neutral wire at transformer TR1 (Figure 11, Item 3) terminal TR1-X0 (Figure 3) and tighten
11. Route green ground wire to power box ground lug (Figure 11, Item 6).
12. Connect one white ground wire and two green ground wires to power box (Figure 11, Item 4) by installing one
screw (Figure 11, Item 9), one flat washer (Figure 11, Item 8), one new lock washer (Figure 11, Item 7), and
one power box ground lug (Figure 11, Item 6). Tighten hardware (WP 0091).
13. Remove all wire tags.
0052-17