MAINTAINER MAINTENANCE DISCHARGE SERVIEC VALVE REPLACE
Many of the chemicals used while soldering are toxic

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  625    626    627    628    629  630  631    632    633    634    635  
img
.
TM 10-8145-222-23
0065
REPLACE CONTINUED
CAUTION
The discharge tube can kink or be easily bent if not careful. Use care when removing
discharge service valve from discharge tube so that tube is not bent or otherwise
damaged during removal.
5. Remove two bolts (Figure 1, Item 1) and two washers (Figure 1, Item 2) securing discharge service valve
(Figure 1, Item 3) to compressor (Figure 1, Item 4).
Figure 1. Discharge Service Valve Removal.
0065-2