7. Desolder each end of 1/4-inch receiver pressure solenoid
Figure 1. Discharge Service Valve Removal.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  624    625    626    627    628  629  630    631    632    633    634  
img
. . . . . . . . . . . . . .
TM 10-8145-222-23
0065
MAINTAINER MAINTENANCE
DISCHARGE SERVICE VALVE
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
Face Shield (WP 0097, Item 20)
TM 10-8415-222-10
Gloves, Rubber (WP 0097, Item 21)
WP 0013
Refrigeration Equipment
WP 0014
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
WP 0018
Service Refrigeration Ordnance
WP 0053
Tool Kit (WP 0096, Table 2, Item 6)
TM 10-8145-222-23P
Equipment Condition
Materials/Parts
Refrigeration unit shut down (TM 10-8415-222-10)
Filter Dryer (WP 0111, Item 2)
External power cables disconnected (TM 10-8415-
Threadlocker, Sealing Compound (WP 0097, Item 41)
222-10)
Personnel Required
Utilities Equipment Repairer (2)
REPLACE
WARNING
Compressor lubricating oil is caustic and can cause severe injury to skin and eyes.
Wear gloves and protective face shield whenever contact with compressor lubricating
oil is possible. If contact with eyes is made, flush eyes and seek immediate medical
attention. If contact with skin is made, wash affected area of skin with soap and
water.
1. Pump refrigeration unit down (WP 0014, Service).
2. Disconnect battery negative (-) terminal (WP 0053, Disconnect).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
3. Remove top-left panel (WP 0013, Remove).
4. Remove top-middle panel (WP 0013, Remove).
0065-1