MAINTAINER MAINTENANCE STARTER REPLACE
Figure 3. Starter.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  291    292    293    294    295  296  297    298    299    300    301  
img
. .
TM 10-8145-222-23
0029
REPLACE CONTINUED
5. Place emergency stop switch (Figure 2, Item 1) in PUSH TO STOP position.
Figure 2. Emergency Stop Switch.
6. Remove top-right panel (WP 0013, Remove).
7. Climb off of MTRCS using roof access provided.
NOTE
Removal of the front panel assembly may provide easier access for removal of the
starter.
The heavy red cable is attached to the positive (+) post on the starter.
8. Remove one nut (Figure 3, Item 1), lock washer (Figure 3, Item 2), and washer (Figure 3, Item 3) from starter
positive stud (Figure 3, Item 4).Replace continued