Figure 10. DTS Mounting Bolt.
MAINTAINER MAINTENANCE DRAIN HOSES REPLACE

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  441    442    443    444    445  446  447    448    449    450    451  
img
.
TM 10-8145-222-23
0049
REPLACE CONTINUED
5. Cut the two wires (Figure 11, Item 1) at approximately 6 inches from the sensor.
Figure 11. DTS Wire Splice.
6. Strip the cut wires to allow for proper installation of a butt splice.
7. Strip wires on new DTS back to allow for proper installation of a butt splice.
8. Butt splice the new DTS to the two cut white wires.
 Note that either of the white wires on the new DTS can connect to either of the white wires on the existing
white wires. There is no specific orientation.
9. Place the black protective loom back over the two new butt splices.
10. Fasten the new DTS sensor (Figure 10, Item 3) to the coil frame using the existing bolt (Figure 10, Item 1) and
washer (Figure 10, Item 2).
11. Rebundle the wires and apply wire ties as required to properly secure components.
12. Hinge the grill cover back up and fasten two existing screws
END OF TASK
END OF WORK PACKAGE