TM 10-8145-222-23
MAINTAINER MAINTENANCE
LIGHTING
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
General Mechanic Tool Kit (WP 0096, Table 2, Item 5)
TM 10-8415-222-10
Electrical Connector Maintenance Kit
Equipment Condition
Personnel Required
Refrigeration unit shut down (TM 10-8415-222-10)
Quartermaster and Chemical Equipment Repairer
Insulated container doors open and secure (TM 10-
8415-222-10)
REPLACE
Remove Wall Mounted Light Strip Lamp Assemblies
1. Open control panel access door (Figure 1, Item 1).
2. Place POWER ON/DOWN switch (Figure 1, Item 2) on control panel to DOWN position.
3. Remove protective covering from applicable red light strip lamp assembly (Figure 1, Item 3) wiring (Figure 3,
Item 12) as needed to gain access to splice points. Retain for reinstallation.
4. Tag and cut wiring (Figure 3, Item 12) for red light strip lamp assembly (Figure 1, Item 3) at two splice points
(Figure 1, Item 4).
5. Remove two screws (Figure 1, Item 5) and threaded standoffs (Figure 1, Item 6) securing red light strip lamp
assembly (Figure 1, Item 3) to container wall.
6. Remove red light strip lamp assembly (Figure 1, Item 3).
7. Disconnect white light strip lamp assembly (Figure 1, Item 7) electrical connector (Figure 1, Item 8) from
electrical connector (Figure 1, Item 9).
8. Remove two screws (Figure 1, Item 10) and lock washers (Figure 1, Item 11) securing white light strip lamp
assembly (Figure 1, Item 7) to container wall. Discard lock washers.
9. Remove white light strip lamp assembly (Figure 1, Item 7).
0051-1