Figure 2. Breather.
Figure 1. Light Strip Replace.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  446    447    448    449    450  451  452    453    454    455    456  
img
. . . . .
TM 10-8145-222-23
0051
MAINTAINER MAINTENANCE
LIGHTING
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
General Mechanic Tool Kit (WP 0096, Table 2, Item 5)
TM 10-8415-222-10
Electrical Connector Maintenance Kit
WP 0053
(WP 0096, Table 2, Item 3)
Equipment Condition
Personnel Required
Refrigeration unit shut down (TM 10-8415-222-10)
Battery disconnected (WP 0053)
Quartermaster and Chemical Equipment Repairer
Insulated container doors open and secure (TM 10-
8415-222-10)
REPLACE
Remove Wall Mounted Light Strip Lamp Assemblies
1. Open control panel access door (Figure 1, Item 1).
2. Place POWER ON/DOWN switch (Figure 1, Item 2) on control panel to DOWN position.
3. Remove protective covering from applicable red light strip lamp assembly (Figure 1, Item 3) wiring (Figure 3,
Item 12) as needed to gain access to splice points. Retain for reinstallation.
4. Tag and cut wiring (Figure 3, Item 12) for red light strip lamp assembly (Figure 1, Item 3) at two splice points
(Figure 1, Item 4).
5. Remove two screws (Figure 1, Item 5) and threaded standoffs (Figure 1, Item 6) securing red light strip lamp
assembly (Figure 1, Item 3) to container wall.
6. Remove red light strip lamp assembly (Figure 1, Item 3).
7. Disconnect white light strip lamp assembly (Figure 1, Item 7) electrical connector (Figure 1, Item 8) from
electrical connector (Figure 1, Item 9).
8. Remove two screws (Figure 1, Item 10) and lock washers (Figure 1, Item 11) securing white light strip lamp
assembly (Figure 1, Item 7) to container wall. Discard lock washers.
9. Remove white light strip lamp assembly (Figure 1, Item 7).