REPAIR CONTINUED
Figure 1. MTRCS Skin Patch Repair.
WARNING
The foam insulation will have to be trimmed flush to allow the patch panel to be
installed. Use of a hacksaw blade to trim the hardened foam is required. The
hacksaw blade is sharp and can cause severe cuts to your skin. Use protective
gloves.
10. Use hacksaw blade to carefully cut hardened excess foam insulation so it is flush with surface of skin.
11. Place 8-inch by 10-inch patch panel (Figure 1, Item 2) over damaged area of skin (Figure 1, Item 1).
12. Using pencil or other marking device, mark perimeter (Figure 1, Item 3) of patch panel (Figure 1, Item 2) on
damaged area.
0057-3