Figure 2. Upper Radiator Hose Disconnect.
Figure 4. Channel Bars.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  648    649    650    651    652  653  654    655    656    657    658  
img
.
TM 10-8145-222-23
0068
REPLACE CONTINUED
8. Disconnect and remove radiator overflow tube (Figure 3, Item 1) from radiator (Figure 3, Item 2) and overflow
tank (Figure 3, Item 3). Retain for reinstallation.
9. Remove four hex head screws (Figure 3, Item 4) securing channel bar (Figure 3, Item 5) and overflow tank
(Figure 3, Item 3) to frame (Figure 3, Item 6) and radiator (Figure 3, Item 2).
10. Remove channel bar (Figure 3, Item 5) and overflow tank (Figure 3, Item 3).
Figure 3. Overflow Tank.
11. Remove four hex head screws (Figure 4, Item 1) securing two channel bars (Figure 4, Item 2) to condenser
(Figure 4, Item 3).
12. Remove two screws (Figure 4, Item 4) and washers (Figure 4, Item 5) securing fan shroud (Figure 4, Item 6) to
condenser (Figure 4, Item 3).
0068-4