• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
The MTRCS contains high voltage sources and exposed rotating parts.
Figure 1. Support Arm.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  660    661    662    663    664  665  666    667    668    669    670  
img
. . . . . . . . . . . . . .
TM 10-8145-222-23
0069
MAINTAINER MAINTENANCE
ACCUMULATOR/HEAT EXCHANGER
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
Face Shield (WP 0097, Item 20)
TM 10-8415-222-10
Gloves, Rubber (WP 0097, Item 21)
WP 0013
Refrigeration Equipment
WP 0014
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
WP 0053
Service Refrigeration Ordnance
TM 10-8145-222-23P
Tool Kit (WP 0096, Table 2, Item 6)
Equipment Condition
Personnel Required
Refrigeration unit shut down (TM 10-8415-222-10)
Utilities Equipment Repairer
External electrical power disconnected (TM 10-8415-
222-10)
Refrigeration unit removed (WP 0059)
REPLACE
1. Recover refrigerant (WP 0014, Service).
2. Disconnect battery (WP 0053, Disconnect).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
3. Gain access to top of MTRCS using roof access.
4. Remove top-left panel (WP 0013, Remove).
5. Remove top-middle panel (WP 0013, Remove).
6. Remove front panel assembly (WP 0013, Remove).
7. Remove five bolts (Figure 1, Item 2) and washers (Figure 1, Item 3), and two nuts (Figure 1, Item 4) and
washers (Figure 1, Item 5) securing support arm (Figure 1, Item 1) and support arm bracket (Figure 1, Item 6) to
frame and position out of way of accumulator.
0069-1