REPAIR CONTINUED
23. Carefully slide lifting strap (Figure 18, Item 1) over and behind transformer (Figure 18, Item 2), and position
lifting strap in middle of transformer. Strap must be positioned between power cables wires (orange, black, and
red wires) and transformer on each side of transformer.
24. Secure lifting strap (Figure 18, Item 1) to hoist.
25. Tighten lifting strap (Figure 18, Item 1) to transformer (Figure 18, Item 2) before removing transformer mounting
hardware.
Figure 18. Lifting Strap.
26. Remove four bolts (Figure 19, Item 1), lock washers (Figure 19, Item 2), and washers (Figure 19, Item 3)
securing transformer (Figure 18, Item 2) to power box (Figure 19, Item 4).
Figure 19. Transformer Mounting Bolts.
0083-16