TM 10-8145-222-23
0083
REPAIR CONTINUED
10. Using four bolts, secure electrical box (Figure 14, Item 3) to power box (Figure 15, Item 5). Secure using four
nuts (Figure 15, Item 1), lock washers (Figure 15, Item 2), washers (Figure 15, Item 3), and rubber washers
(Figure 15, Item 4).
11. Close power box cover.
12. Install electrical box cover (Figure 14, Item 2) to electrical box (Figure 14, Item 3) and secure using four screws
(Figure 14, Item 1).
WARNING
Installation of the power box/transformer is performed using a forklift. The forklift
operator must be aware of ground personnel at all times. Forklift can cause damage
to equipment.
Always use hearing and head protection when working with or around a forklift. A
forklift engine puts out high noise that can cause serious hearing damage. Many
head injury hazard possibilities exist while using a forklift, such as falling loads and
collision with the forklift itself. Head related injuries can cause serious additional
health hazards or even death to personnel.
CAUTION
When positioning the power box onto the fork lift tines to support, make sure that you
do not trap any wires between the forklift tines and the bottom of the power box.
13. Use three persons to lift power box (Figure 13, Item 1) onto forklift with bottom of power box resting on forklift
tines (Figure 23).
14. Slowly move forklift, with power box, towards MTRCS.
Figure 23. Lifting Power Box with Forklift.