Figure 2. Alternator Removal.
23. Remove condenser fan (Figure 4, Item 3) from standby motor shaft

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  735    736    737    738    739  740  741    742    743    744    745  
img
.
TM 10-8145-222-23
0077
REPLACE CONTINUED
17. Remove two screws (Figure 1, Item 6) and washers (Figure 1, Item 7) securing fan shroud (Figure 1, Item 8) to
radiator (Figure 1, Item 9).
18. Remove fan shroud (Figure 1, Item 8). Retain for reinstallation.
Figure 3. Alternator Attaching Hardware Removal.