  904    905    906    907    908  909  910    911    912    913    914  
img
. . . . . . .
TM 10-8145-222-23
0089
MAINTAINER MAINTENANCE
DOORS
REPAIR
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Quartermaster and Chemical Equipment Repairer (2)
SATS (WP 0096, Table 2, Item 8)
References
Materials/Parts
WP 0057
TM 10-8145-222-23P
Alcohol, Isopropyl (WP 0097, Item 2)
Oil, Lubricating, General Purpose
Equipment Condition
(WP 0097, Item 13)
Refrigeration unit shut down (TM 10-8415-222-10)
Insulated container doors open and secure
(TM 10-8415-222-10)
REPAIR
Skin Repair
Skin repair can be accomplished in accordance with WP 0057.
Replace Door Seals
NOTE
This procedure is applicable to both rear door gaskets and also the side door gasket.
Only one door will be referenced in the procedure.
1. Open applicable doors (Figure 1, Item 1) on container (Figure 1, Item 2) and secure open with chain.
Apply lubricant between outer seal (Figure 1, Item 3) and door (Figure 1, Item 1).
Figure 1. MTRCS Door Seals.