TM 10-8145-222-23
0033
REPLACE CONTINUED
9. Place positive multimeter lead on each replacement glow plug (Figure 4, Item 3) and negative multimeter lead
on engine block ground.
Resistance indicated on meter should be between 0.7 and 1.2 ohms for each glow plug.
10. Carefully install replacement glow plugs (Figure 4, Item 3) into cylinder head (Figure 4, Item 5).
NOTE
There are three glow plugs associated with this engine. An ohm reading check must
be performed on each glow plug to assess if a plug is faulty and needs to be
replaced.
11. Retest each glow plug after installation by placing positive multimeter lead on each glow plug (Figure 4, Item 3)
and negative multimeter lead on engine block ground.
Resistance indicated on meter should be between 0.7 and 1.2 ohms for each glow plug.
12. Tighten each glow plug (Figure 4, Item 3) and torque 6 to 11 foot-pounds (WP 0091, Introduction).
13. Install glow plug lead assembly (Figure 4, Item 2).
14. Connect electrical lead (Figure 4, Item 4) to glow plug lead assembly (Figure 4, Item 2).
15. Install three nuts (Figure 4, Item 1) to secure glow plug lead assembly (Figure 4, Item 2) to three glow plugs
(Figure 4, Item 3).
16. Install top-right panel (WP 0013, Install).
17. Place emergency stop switch (Figure 2, Item 1) in PULL TO START position.
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
18. Climb off top of MTRCS using roof access provided.
19. Reconnect negative (-) battery terminal (WP 0053, Reconnect).
20. Place POWER ON/DOWN switch (Figure 1, Item 1) on control panel to ON position.
21. Operate MTRCS to verify proper operation (TM 10-8415-222-10, Operating Procedures).
22. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE
0033-6