TEST ­ CONTINUED
REPLACE ­ CONTINUED

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  323    324    325    326    327  328  329    330    331    332    333  
img
. .
TM 10-8145-222-23
0033
REPLACE CONTINUED
4. Remove top-right panel (WP 0013, Remove).
5. Remove three nuts (Figure 4, Item 1) securing glow plug lead assembly (Figure 4, Item 2) to three glow plugs
(Figure 4, Item 3).
6. Disconnect electrical lead (Figure 4, Item 4) from forward glow plug.
7. Remove glow plug lead assembly (Figure 4, Item 2).
8. Loosen each glow plug (Figure 4, Item 3) and remove from cylinder head (Figure 4, Item 5).
Figure 4. Glow Plug Lead Assembly Replacement.