TM 10-8145-222-23
MAINTAINER MAINTENANCE
REPLACE
INITIAL SETUP:
Tools and Special Tools
References
TM 10-8415-222-10
Refrigeration Equipment
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
Service Refrigeration Ordnance
TM 10-8145-222-23P
Materials/Parts
Equipment Condition
Refrigeration unit shut down (TM 10-8415-222-10)
Detergent, General Purpose
External power cable disconnected (TM 10-8415-222-
10)
Personnel Required
Utilities Equipment Repairer
REPLACE
WARNING
The MTRCS contains high voltage sources and exposed rotating parts. Make sure
that power cables are disconnected from the MTRCS and that the refrigeration unit is
shut down before performing maintenance on the unit. Failure to comply with this
warning can result in serious injury or death to personnel.
Beware of V-belts and belt driven components. The refrigeration unit may start
automatically. Before performing maintenance on any belt driven system, make sure
that the power to the unit is off.
1. Disconnect negative (-) battery terminal (WP 0053, Disconnect).
WARNING
Falling from the top of the MTRCS can result in serious injury or death to personnel.
Whenever performing maintenance on top of the MTRCS, always maintain three
points of contact to aid in stability. Never attempt to walk backwards while on top of
the container.
2. Access top of MTRCS using roof access provided.
3. Make sure emergency stop switch (Figure 1, Item 1) is in PUSH TO STOP position.
0034-1