TM 10-8145-222-23
0040
REPLACE CONTINUED
11. Place emergency stop switch (Figure 4, Item 1) in PULL TO START position.
12. Install top-right panel (WP 0013, Install).
13. Exit top of MTRCS using roof access provided.
14. Place POWER ON/DOWN switch (Figure 1, Item 2) on control panel to ON position.
CAUTION
If alarm code is displayed or audible alarm sounds, shut the diesel engine down
immediately by placing the POWER ON/DOWN switch to the DOWN position. Failure
to observe this caution can damage the diesel engine.
15. Operate diesel engine and check that alarm code ENGINE OIL (or alarm code AL0 if coded display is used) is
not displayed on microprocessor controller display (Figure 1, Item 3) (TM 10-8415-222-10, Operating
Procedures).
16. Monitor diesel engine operation for five minutes. If no alarms sound or display on microprocessor display
(Figure 1, Item 3), operate engine normally.
17. Close control panel access cover (Figure 1, Item 1).
18. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
Figure 4. Emergency Stop Switch.
END OF TASK
END OF WORK PACKAGE