REPLACE CONTINUED
10. Install new idler assembly shaft (Figure 2, Item 7) through idler pulley (Figure 2, Item 8) and bracket (Figure 2,
Item 4)
11. Install idler (Figure 2, Item 3) and washer (Figure 2, Item 6) onto idler assembly shaft (Figure 2, Item 7) and
secure in place using new lock nut (Figure 2, Item 5).
NOTE
Adjustment of the tensioner adjustment bolt will be accomplished during the
reinstallation of the engine to compressor V-belt.
12. Install tensioner adjustment bolt (Figure 2, Item 1) and nut (Figure 2, Item 2) through bracket (Figure 2, Item 4)
and into idler (Figure 2, Item 3).
13. Install engine to compressor V-belt (WP 0037, Install).
14. Install top-middle panel (WP 0013, Install).
15. Install top-right panel (WP 0013, Install).
16. Place emergency stop switch (Figure 1, Item 1) is in PULL TO START position.
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
17. Exit top of MTRCS using roof access.
18. Perform refrigeration unit operation under usual conditions (TM 10-8415-222-10, Operating Procedures).
19. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
1. Access top of MTRCS using roof access.
2. Make sure emergency stop switch (Figure 1, Item 1) is in PUSH TO STOP position.
4. Remove top-middle panel (WP 0013, Remove).