Figure 9. Overload Protector and Motor Contactor.
Replace Relay

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  792    793    794    795    796  797  798    799    800    801    802  
img
. .
TM 10-8145-222-23
0079
REPAIR CONTINUED
Replace Relay Board Fuse
1. Remove fuse (Figure 10, Item 1) by pulling fuse from fuse socket (Figure 10, Item 2).
2. Verify amperage on new fuse (Figure 10, Item 1) is same as old fuse.
3. Install fuse (Figure 10, Item 1) into fuse socket (Figure 10, Item 2).
4. Reconnect battery negative (-) terminal (WP 0053, Connect).
5. Operate unit in accordance with normal operating procedures to verify proper operation after replacement of
fuse (TM 10-8415-222-10, Operating Procedures).
6. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
Figure 10. Relay Board Fuses.
0079-17