Replace Fuse F1
Flashing Relay and Electric Motor Relay Replace

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  786    787    788    789    790  791  792    793    794    795    796  
img
.
TM 10-8145-222-23
0079
REPAIR CONTINUED
Evaporator Heater Relay Replace
1. Locate 1EHR (Figure 6, Item 1) and 2EHR (Figure 6, Item 2) relays on the back panel.
2. Tag and remove 8 wires (Figure 6, Item 3) on the 1EHR or 2EHR relay.
3. Remove four screws (Figure 6, Item 4), washers (Figure 6, Item 5) and 1EHR (Figure 6, Item 1) or 2EHR
(Figure 6, Item 2) relay.
4. Install new 1EHR (Figure 6, Item 1) or 2EHR (Figure 6, Item 2) relay by reinstalling the four screws (Figure 6,
Item 4) and washers (Figure 6, Item 5).
5. Reconnect the 8 wires (Figure 6, Item 4) to the relay as tagged.
Figure 6. Evaporator Heater Relay.
0079-11