REPLACE ­ CONTINUED
Figure 1. Compressor Discharge Temperature Sensor.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  236    237    238    239    240  241  242    243    244    245    246  
img
. . . . . . . . . . .
TM 10-8145-222-23
0020
MAINTAINER MAINTENANCE
COMPRESSOR SENSORS
REPLACE, TEST
INITIAL SETUP:
Tools and Special Tools
Personnel Required
Face Shield (WP 0097, Item 20)
Utilities Equipment Repairer
Gloves, Rubber (WP 0097, Item 21)
References
Pail, Utility (Metal) (WP 0097, Item 34)
Refrigeration Equipment
TM 10-8145-222-10
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
WP 0013
Service Refrigeration Ordnance
WP 0014
Tool Kit (WP 0096, Table 2, Item 6)
TM 10-8145-222-23P
Materials/Parts
Equipment Condition
Tie Wrap (WP 0097, Item 55)
Refrigeration unit shut down (TM 10-8145-222-10)
Top-middle panel and right side removed (WP 0013)
REPLACE
Compressor Discharge Temperature Sensor
WARNING
Falling from the roof of the MTRCS can cause serious personal injury or death. Keep
three points of contact on the MTRCS at all times.
1. Disconnect electrical connector (Figure 1, Item 1) from Compressor Discharge Temperature (CDT) sensor
(Figure 1, Item 2). Cut tie wraps as necessary.
2. Remove CDT sensor (Figure 1, Item 2) from compressor (Figure 1, Item 3).
3. Install new CDT sensor (Figure 1, Item 2) to compressor (Figure 1, Item 3).
4. Reconnect electrical connector (Figure 1, Item 1) to CDT sensor (Figure 1, Item 2). Install tie wraps as
necessary.
5. Install top-middle panel (WP 0013, Install).
0020-1