TM 10-8145-222-23
MAINTAINER MAINTENANCE
EVAPORATOR BLOWER MOTOR
REPLACE
INITIAL SETUP:
References
Tools and Special Tools
TM 10-8415-222-10
Service Refrigeration Ordnance
TM 10-8415-222-10
Refrigeration Equipment
Tool Kit (supplement) (WP 0096, Table 2, Item 7)
TM 10-8145-222-23P
Materials/Parts
Equipment Condition
Lock Washer, 3/8-in ID (WP 0111, Item 13)
Refrigeration unit shut down (TM 10-8415-222-10)
External power cables disconnected (TM 10-8415-
Personnel Required
222-10)
Utilities Equipment Repairer
REPLACE
NOTE
There are two compartments within the MTRCS accommodate cooling and freezing
of perishable items. Each compartment is operated independently of the other and
has a separate evaporator unit.
Each evaporator contains two evaporator blower motors. Removal and reinstallation
of the blower motors is the same for each evaporator. The replacement procedure for
each evaporator addresses removal of one blower motor only.
Remove
1. Open control panel assembly door (Figure 1, Item 1).
2. On control box, place COMPARTMENT 1 ON/OFF rocker switch (Figure 1, Item 2) to OFF position.
3. Place COMPARTMENT 2 ON/OFF rocker switch (Figure 1, Item 3) to OFF position.
4. Place POWER ON/DOWN switch (Figure 1, Item 4) to DOWN position.
5. Close control panel assembly door (Figure 1, Item 1) and latch (Figure 1, Item 5).
6. Disconnect battery negative (-) terminal (WP 0053, Disconnect).
WARNING
MTRCS doors are very heavy and solid objects. Make sure rear doors are secured to
container frame when in the open position. A gust of wind can cause unsecured
doors to slam shut with great force possibly causing severe injury or death to
personnel.
7. Open MTRCS rear and side access doors and secure open (TM 10-8415-222-10, Preparation).
0043-1